| Off-Grid Pure Sine Wave Inverter | 
						 
						
							| 
								Views:7839 | 
						 
						 | 
						 
						|   |  
						
							
| 
 Model  | 
 WS12500  | 
 WS24500  | 
 WS241000  | 
 WS481000  | 
 WS482000  | 
 WS483000  |  
| 
 DC Input Voltage (V Dc)  | 
 12V  | 
 24V  | 
 24V  | 
 48V  | 
 48V  | 
 48V  |  
| 
 Other Voltage is Available, Please Confirm Before Order  |  
| 
 Continuous Power Rating  | 
 500W  | 
 500W  | 
 1000W  | 
 1000W  | 
 2000W  | 
 3000W  |  
| 
 Typical Efficiency  | 
 96%  |  
| 
 Total Harmonic Distortion  | 
 ≤3%  |  
| 
 Output Wave  | 
 Pure Sine Wave  |  
| 
 Output Voltage  | 
 Single phase  220V/50HZ  120V/60HZ  |  
| 
 Output Voltage Precision  | 
 220V ± 3% 
120V ± 3%  |  
| 
 Output Frequency Precision  | 
 50 ± 0.1% 
60 ± 0.1%  |  
| 
 Overload Ability  | 
 120%  60 Seconds  |  
| 
 Protection  | 
 Input Polarity Reverse Protection ;Lower Voltage Protection ; 
Over Voltage Protection; Over Load Protection ; 
Short Circuit Protection; Over Heating Protection  |  
| 
 Isolation  | 
 Input VS Output: AC 1500V 60 Seconds  |  
| 
 Operation  Temperature  | 
 0%~90%, -250C~+550C  |  
| 
 Humidity  | 
 0%~90%, Non-condensing  |  
| 
 Noise  | 
 ≤45db  |  
| 
 Operation Altitude (m)  | 
 ≤2500  |    
  
  
  
  
  
   
  
  
  
| 
 Model  | 
 WS485000  | 
 WS24010000  | 
 WS24010000-3  | 
 WS48020000-3  | 
 WS48030000-3  |  
| 
 DC Input Voltage (V Dc)  | 
 48V  | 
 240V  | 
 240V  | 
 480V  | 
 480V  |  
| 
 Other Voltage is Available, Please Confirm Before Order  |  
| 
 Continuous Power Rating  | 
 5kw  | 
 10kw  | 
 10kw  | 
 20kw  | 
 30kw  |  
| 
 Typical Efficiency  | 
 92%  |  
| 
 Total Harmonic Distortion  | 
 ≤3%  |  
| 
 Output Wave  | 
 Pure Sine Wave  |  
| 
 Output Voltage  | 
 Single Phase 
120V/60Hz 220V/50Hz  | 
 Three Phase 
480V/60Hz  380V/50Hz  |  
| 
 Output Voltage Precision  | 
 220V ± 3%,    120V ± 3%  |  
| 
 Output Frequency Precision  | 
 50 ± 0.1%,    60 ± 0.1%  |  
| 
 Overload Ability  | 
 10 seconds 120%  |  
| 
 AC Input (Optional)  | 
 By Pass(Optional) 
Single phase: 120V/60Hz;220V/50Hz; 240V/50Hz 
(5KW,10KW also can provide three phase)  |  
| 
 Protection  | 
 Input Polarity Reverse Protection ;Lower Voltage Protection ; 
Over Voltage Protection; Over Load Protection ; 
Short Circuit Protection; Over Heating Protection  |  
| 
 Communication Interface  | 
 RS232/485(Optional)  |  
| 
 Isolation  | 
   Input VS Output: AC 1500V 60 Seconds  |  
| 
 Operation  Temperature  | 
 -250C~+550C  |  
| 
 Humidity  | 
 0%~90%,Non-condensing  |  
| 
 Noise  | 
 ≤50Db  |  
| 
 Operation Altitude (m)  | 
 ≤2500  |    
   | 
						 
						
					 
				 |